Condition
In an approved simulator or aboard a ship in port or at anchor, given access to a main boiler.
Performance requirement
Behavior | Standard |
---|---|
The student will: | During assessment, the student shall, at a minimum: |
Check and prepare boiler for light off |
Insure adequate water in drum Open:
|
Light off boiler |
Start forced draft Open dampers and purge furnace Light fires Correctly proportion fuel/air ratio to prevent smoke |
Monitor boiler |
Monitor:
|
Location
Assessed in EN‑3131 Steam Generators.
References
STCW Knowledge, Understanding and Proficiency
NVIC Tasks
- NVIC 07-14 Task 3.1.F Assist preparing a main-propulsion boiler for light-off
- NVIC 07-14 Task 3.1.G Assist in manual light-off, raising steam and cutting-in a boiler
- NVIC 17-14 Task 4.1.B Light off boiler
See the Assessment Guidelines for additional specifications of behavior and standards.