Condition
Using an approved simulator, in the laboratory, or aboard ship, given access to a fuel oil or lube oil purifier.
Performance requirement
Behavior | Standard |
---|---|
The student will: | During assessment, the student shall, at a minimum: |
Identify the valves and equipment associated with the purifier unit |
Identify:
|
Line-up purifier unit |
Line up correct valves from suction to discharge |
Start the purifier |
Start prime mover and bring up to speed Secure if excessive vibration is noted Prime purifier Verify:
|
Monitor the purifier until conditions stabilize |
Monitor:
|
Location
Assessed in EN‑3233 Steam and Gas Turbines.
References
STCW Knowledge, Understanding and Proficiency
NVIC Tasks
- NVIC 17-14 Task 4.3.R Start oil purifier
See the Assessment Guidelines for additional specifications of behavior and standards.